A Generator Maintenance Checklist for Houston Homeowners
A standby generator that has not been serviced is the one most likely to fail when you need it.

Generac Prestige DealerGenerac's highest dealer designation. We sell, install and service Generac home standby generators.
Generac generatorsA Generator Maintenance Checklist for Houston Homeowners
What you can do: look for debris, leaves or anything stacked against the unit, keep the area around it clear, and check the display for fault messages. What a technician should do: change the oil and filters, test the battery, inspect the unit and the transfer switch, and run it under load, following the manufacturer's service schedule. Keep a record of each visit, because some warranties expect it.
If you see a fault code, hear unusual noise, or the unit did not start in a recent outage, call us rather than waiting for the next storm.
Every week: what you can check
These take a minute and need no tools. Leave the enclosure closed and latched, and never open the transfer switch.
- Know what day and time your generator exercises, and listen for it now and then
- Check that the controller is in AUTO and the status light shows ready
- Look for alarms, warnings or a maintenance reminder on the display
- Look for oil or fuel leaks around the unit and the pad
- Keep leaves, mulch, shrubs and stored items out of the clearance area
- On propane, check the tank level, especially before storm season
If it missed its test, shows a warning or sounds different, write down what you saw and call us at (713) 467-1125.
Once a year: the service visit
Once a year is what we recommend for most home units, and more after heavy storm use. Book it before hurricane season, when there is time to order a part. A technician should:
- Change the engine oil and oil filter
- Inspect the air filter and replace it if needed
- Test the battery, spark plugs and connections
- Inspect the fuel system, wiring and connectors for leaks, damage or corrosion
- Check for controller firmware updates, where they apply
- Run the engine and check startup, shutdown, temperatures and pressures
- Inspect the transfer switch and run a transfer with your approval
- Send you a summary report with anything else that needs work
The transfer test shuts your power off for a moment while the house moves to the generator and back. It is the only way to know the whole system works before a storm, not just the engine. Our generator maintenance page has the full service list, and Shield Protection plans put it on a schedule.
Extra items on liquid-cooled and diesel units
Most home standby generators are air-cooled. Air-cooled units have no coolant, drive belts or diesel fuel, so those items do not apply to them. Larger liquid-cooled units add coolant, hoses, belts and a radiator to the list, and the visit takes longer. Diesel units also need fuel testing and any water removed from the fuel tank. If you are not sure which type you have, the model number on the data label tells us.
After a storm or a long outage
Look the unit over once the weather clears: debris on or against the enclosure, standing water or washed-out soil around the pad, and anything leaning on it. After a long outage, have it serviced too, since it has just done the hardest work of its life. Keep a simple log of every visit and every fault message, because some warranties expect a service record.
Ask us anything. These come up most.
How often should a generator be serviced?
Follow the manufacturer's schedule for your unit, which is at least once a year for most home standby generators.
Can I do the maintenance myself?
You can keep the area clear and watch for fault messages. Service work and load testing should be done by a trained technician.
Is the weekly exercise the same as maintenance?
No. The weekly self-test keeps the engine lubricated and confirms it can start. It does not change the oil, test the battery under load or confirm the transfer switch moves the house over.
Does an air-cooled generator need coolant or belt service?
No. Air-cooled home units have no coolant, drive belts or diesel fuel. Those items apply to liquid-cooled and diesel units.
What if my generator was installed by another company?
We can still service it. The first visit is a catch-up: we check the unit, the pad, the gas line and the transfer switch, tell you what is overdue and put it on a yearly schedule.
From first call to finished job.
Estimates are free. Call any time, day or night.